HVAC

Airflow Balometer

The EBT731 Balometer® Capture Hood is a multipurpose electronic air balancing instrument primarily used for efficiently taking direct air volume readings at diffusers and grilles. The EBT features a detachable micromanometer which can be used with optional probes for increased flexibility in multiple measurement applications.

• Ergonomic design and ultra-light weight for easy, one-person operation
• Automatically senses and displays supply or return flows, saving time on the job
• Back pressure compensation ensures accurate readings

Airflow Hot Wire

Accurate air velocity measurement over a wide velocity range Simultaneously measures and displays velocity, temperature and humidity. Calculates volumetric flow, wet bulb and dew point, temperature Data logging. Ideal applications include HVAC system performance, commissioning, plant maintenance, critical environment certification and duct traverses.

• Accurate air velocity measurement
• Large, easy to read display
• Calibration certificate included

Airflow LCA501 Anemometers

• Ideal applications include supply and extract grilles and flow hood balancing, HVAC commissioning and trouble shooting, laboratory safety monitoring and air conditioning and ventilation duct checks.
• Measures velocity and temperature
• Sweep mode for one overall measurement
• Log, store, and recall data
• Download data to a PC
• Optional telescopic probe available
• Clear digital display
• Model LCA501 is a light weight, robust, and simple to use Rotating Vane Anemometer that provides accurate and reliable readings every time. Reversible 100 mm head allows readings at supply and extract grilles
• Calculates volumetric flow rate

Airflow Micromanometers

Model PVM610

The PVM610 is an easy to use, hand held digital Micromanometer for fast, accurate and reliable pressure measurement. It can also calculate velocity.

Model PVM620

The PVM620 is a rugged, compact, comprehensive Micromanometer that measures pressure, and calculates velocity and volumetric flow rate. It can be used with Pitot tubes to measure velocity and then calculate flow rates with user–input duct size and shape. Premium features make it ideal for HVAC, environmental safeguards, commissioning, process control and system balancing.

• Measure differential and static pressure from -3735 to +3735 Pa -15 to +15 in. H2O)
• Calculate and display velocity when using a Pitot tube
• Calculates volumetric flow rate in duct from velocity and user-input duct size and shape

Airflow Panda

The Airflow™ Instruments Positive and Negative Duct Accreditation (PANDA) System PAN341 Series provides contractors, commissioning engineers, and research and development technicians with the best in class choice of test equipment to quantify air leakage in ductwork and other areas as well as the ability to measure the performance of ducted systems.

• Positive and negative duct accreditation (panda) system
• Positive and negative duct leakage testing in one rig
• Energy savings by testing and minimizing duct leaks

Greisinger PH & Temperature

For comfortable measurements of pH value and temperature. Even easier operation ensured by a menu reduced to  5 points for GMH 3511. Minimal measuring effort because  of maintenance-free gel-electrode and automatic temperature compensation.

Specifications:
p.r.t. GHM 3511 Scope of supply: GMH 3511, pH electrode GE 114,  temperature probe GTF 55 B, buffer capsules 5 x GPH 4, 5 x GPH  7, 2 plastic wide mouth bottles

 

• For comfortable measurements of pH value and temperature Double display for pH or redox and temperature
• Redox mode allows for automatic conversion to a hydrogen system.
• Automatic or manual temperature compensation
• Automatic buffer detection

Pressura – For Critical Environments

The PresSura™ Model RPM10 Room Pressure Monitor is designed to accurately measure pressure differentials in hospital isolation rooms and operating rooms. Backed by TSI’s unique thermal-based pressure sensor, the PresSura products offer the most accurate, precise, and stable measurement available.

A local monitor provides easy visual indication of room status. If pressure is lost, the system activates audible and visual alarms, alerting staff to the alarm condition. The system features adjustable alarm delays to avoid nuisance alarms. When the room is unoccupied, the system can be changed to no isolation mode, deactivating all alarms.

• Continuously measures room pressure
• Audible, visual alarms warn of loss of containment
• Accepts optional key switch for use when room is not occupied
• Communicates with building management system using analog output

TSI 7545

• Temperature and relative humidity measurements help determine thermal comfort
• Directly calculates dew point and wet bulb temperatures
• Electrochemical sensor measures CO
• Calculates % outside air from either CO2 or temperature

Contact Us